Chapter at a glance
Comprehensive solutions and study guide for Class 12 Chemistry Chapter 1 Volumetric Analysis covering concentration units, equivalent weight formulas, primary and secondary standards, titration equivalence principles, and indicator selection.
- Concentration Expressions (Molarity, Normality, Molality, ppm)
- Equivalent Weight of Acids, Bases, Salts, and Redox Reagents
- Primary Standards vs Secondary Standards Characteristics
- The Law of Equivalence and Titration Equation N1 V1 = N2 V2
- pH Curves and Indicator Selection for Neutralization Titrations
Exam focus: Solving numericals on standardization of acids/bases, finding percentage purity of chemical samples, and converting between concentration units.
Key formulas and definitions
- Molarity: M = (w * 1000) / (M_w * V_mL)
- Normality: N = (w * 1000) / (E * V_mL)
- Equivalent Weight: E = M_w / n-factor
- Law of Equivalence: N1 V1 = N2 V2
- Relation: N = M * n-factor
On this page (12 sections)
- The lesson in short
- Section A: Concentration Units and Equivalent Weight
- Concentration UnitsStandard Expressions of Solution Concentration
- FormulasThe Concept of Equivalent Weight (E)
- Section B: Principles of Titration and Indicators
- StandardsPrimary vs Secondary Standard Substances
- Core LawThe Principle of Volumetric Analysis (Law of Equivalence)
- IndicatorsAcid-Base Indicators & Selection Criteria
- Section C: Step-by-Step Solved Problems
- Problem 1Problem 1: Standardizing an Acid Against Primary Base Standard
- Problem 2Problem 2: Percentage Purity of an Impure Alkali Sample
- Problem 3Problem 3: Calculating Concentration in Multiple Units
Solutions and answers
The lesson in short
Volumetric analysis (titrimetric analysis) is a quantitative chemical technique in analytical chemistry used to determine the unknown concentration of an analyte by measuring the exact volume of a standard reagent solution required for complete stoichiometric reaction.
From water quality testing (hardness, dissolved oxygen) and pharmaceutical drug assays to food acidity verification and environmental emissions monitoring, volumetric titrations provide rapid, accurate quantitative analytical measurements.
This chapter covers units of concentration (molarity, normality, molality, ppm, mass percentage), primary and secondary standards, equivalent weight concepts, acid-base neutralization reactions, indicators and pH color transitions, and stoichiometric titration calculations aligned with the NEB Class 12 curriculum.
Section A: Concentration Units and Equivalent Weight
Concentration UnitsStandard Expressions of Solution Concentration
| Concentration Term | Symbol & Definition Formula | Units | Temperature Dependence |
|---|---|---|---|
| Molarity | M = (Moles of Solute) / (Volume of Solution in Liters) = (w × 1000) / (M_w × V_mL) | mol/L (or M) | Temperature dependent (solution volume expands with heat) |
| Normality | N = (Gram Equivalents of Solute) / (Volume in Liters) = (w × 1000) / (E × V_mL) | eq/L (or N) | Temperature dependent; related to molarity by N = M × n-factor |
| Molality | m = (Moles of Solute) / (Mass of Solvent in kg) = (w × 1000) / (M_w × W_solvent) | mol/kg (or m) | Temperature independent (mass remains constant) |
| Parts per Million (ppm) | ppm = (Mass of Solute / Total Mass of Solution) × 10⁶ | ppm (mg/L) | Convenient for trace pollutants and water hardness |
| Mass Percentage (% w/w) | % (w/w) = (Mass of Solute / Mass of Solution) × 100 | % | Temperature independent |
FormulasThe Concept of Equivalent Weight (E)
The equivalent weight of a substance is the mass in grams that combines with or displaces 1.008 g of hydrogen, 8.0 g of oxygen, or 35.5 g of chlorine: Equivalent Weight (E) = (Molecular Weight or Atomic Weight) / (n-factor).
- Acids: n-factor = Basicity (number of replaceable H⁺ ions per molecule). E.g., for H₂SO₄, M_w = 98, basicity = 2 ⟹ E = 98 / 2 = 49.
- Bases: n-factor = Acidity (number of replaceable OH⁻ ions per molecule). E.g., for NaOH, M_w = 40, acidity = 1 ⟹ E = 40 / 1 = 40; for Ca(OH)₂, M_w = 74, acidity = 2 ⟹ E = 37.
- Salts: n-factor = Total positive valency of metal ions. E.g., for Na₂CO₃, M_w = 106, total positive charge = 2(+1) = 2 ⟹ E = 106 / 2 = 53.
- Oxidizing / Reducing Agents: n-factor = Total number of electrons transferred per molecule. E.g., KMnO₄ in acidic medium reduces from Mn⁺⁷ to Mn⁺² (5 electrons gained) ⟹ E = M_w / 5 = 158 / 5 = 31.6.
Section B: Principles of Titration and Indicators
StandardsPrimary vs Secondary Standard Substances
| Property | Primary Standard | Secondary Standard |
|---|---|---|
| Purity & Composition | Extremely pure (>99.9%), stable composition | Less pure, hygroscopic or unstable composition |
| Solution Preparation | Standard solution can be prepared by direct weighing | Solution prepared approximately and standardized against primary standard |
| Examples | Anhydrous Na₂CO₃, Oxalic acid ((COOH)₂·2H₂O), K₂Cr₂O₇ | NaOH, KOH (absorbs moisture/CO₂), HCl, H₂SO₄, KMnO₄ |
Core LawThe Principle of Volumetric Analysis (Law of Equivalence)
At the exact equivalence point (end point) of a chemical titration, the number of gram equivalents of the reacting species are strictly equal: Gram Equivalents of Acid = Gram Equivalents of Base.
Expressed via normality and volume: N₁ × V₁ = N₂ × V₂ (where V must be expressed in matching volumetric units).
IndicatorsAcid-Base Indicators & Selection Criteria
| Titration Combination | pH at Equivalence Point | Suitable Indicator | Color Change at End Point |
|---|---|---|---|
| Strong Acid vs Strong Base | pH ≈ 7.0 (sharp inflection pH 3.5 to 10.5) | Phenolphthalein or Methyl Orange | Colorless to pink (or pink to yellow) |
| Strong Acid vs Weak Base | pH < 7.0 (acidic due to cationic hydrolysis) | Methyl Orange (pH range 3.1 - 4.4) | Yellow to pink / orange |
| Weak Acid vs Strong Base | pH > 7.0 (basic due to anionic hydrolysis) | Phenolphthalein (pH range 8.3 - 10.0) | Colorless to distinct pink |
| Weak Acid vs Weak Base | pH varies around 7 (no sharp inflection) | No standard indicator suitable | Potentiometric / conductometric titration required |
Section C: Step-by-Step Solved Problems
Problem 1Problem 1: Standardizing an Acid Against Primary Base Standard
2.65 g of anhydrous sodium carbonate (Na₂CO₃) was dissolved in water to prepare exactly 250 mL of standard solution. 20 mL of this solution required 25 mL of an unknown hydrochloric acid (HCl) solution for complete neutralization. Calculate the normality and molarity of the HCl solution.
Step 1: Calculate the equivalent weight of anhydrous Na₂CO₃:
Molecular weight of Na₂CO₃ = 2(23) + 12 + 3(16) = 46 + 12 + 48 = 106.
Basicity / Total positive charge of cation = 2(+1) = 2.
Equivalent weight E = 106 / 2 = 53.
Step 2: Find normality of the standard Na₂CO₃ solution (N₁):
N₁ = (w × 1000) / (E × V_mL) = (2.65 × 1000) / (53 × 250) = 2650 / 13250 = 0.2 N.
Step 3: Apply the Law of Equivalence (N₁ V₁ = N₂ V₂):
N₁ = 0.2 N, V₁ = 20 mL (volume of Na₂CO₃ taken)
V₂ = 25 mL (volume of HCl consumed), N₂ = normality of HCl
N₁ V₁ = N₂ V₂ ⟹ 0.2 × 20 = N₂ × 25 ⟹ 4.0 = 25 N₂ ⟹ N₂ = 4.0 / 25 = 0.16 N.
Step 4: Convert normality of HCl to molarity:
For monobasic hydrochloric acid (HCl), n-factor = 1.
Molarity = Normality / n-factor = 0.16 / 1 = 0.16 M.
Answer: Normality of HCl = 0.16 N; Molarity of HCl = 0.16 M.
Problem 2Problem 2: Percentage Purity of an Impure Alkali Sample
A 1.00 g sample of impure caustic soda (NaOH) is dissolved in water and neutralized by exactly 40 mL of 0.5 N H₂SO₄. Calculate the percentage purity of the NaOH sample.
Step 1: Determine the gram equivalents of H₂SO₄ consumed:
Gram equivalents of acid = (Normality × Volume in mL) / 1000 = (0.5 × 40) / 1000 = 20 / 1000 = 0.02 equivalents.
Step 2: Apply the Law of Equivalence:
Gram equivalents of pure NaOH = Gram equivalents of H₂SO₄ consumed = 0.02 equivalents.
Step 3: Compute the mass of pure NaOH present in the sample:
Equivalent weight of NaOH = Molecular weight / 1 = 40 / 1 = 40 g/eq.
Mass of pure NaOH = Gram equivalents × Equivalent weight = 0.02 × 40 = 0.80 g.
Step 4: Calculate the percentage purity:
Percentage purity = (Mass of pure NaOH / Mass of impure sample) × 100 = (0.80 g / 1.00 g) × 100 = 80.0%.
Answer: The purity of the caustic soda sample is 80.0%.
Problem 3Problem 3: Calculating Concentration in Multiple Units
A commercial aqueous solution of nitric acid (HNO₃) has a density of 1.42 g/mL and contains 63% (w/w) HNO₃. Calculate its molarity, normality, and molality (Molar mass of HNO₃ = 63 g/mol).
Step 1: Consider 1000 mL (1 Liter) of the nitric acid solution:
Mass of 1000 mL solution = Volume × Density = 1000 mL × 1.42 g/mL = 1420 g.
Mass of pure HNO₃ solute = 63% of 1420 g = 0.63 × 1420 = 894.6 g.
Step 2: Calculate Molarity:
Moles of HNO₃ = Mass / Molar mass = 894.6 / 63 = 14.2 mol.
Since this is contained in exactly 1 Liter of solution: Molarity = 14.2 M.
Step 3: Calculate Normality:
Since HNO₃ is a monoprotic acid (basicity = 1), Normality = Molarity × 1 = 14.2 N.
Step 4: Calculate Molality:
Mass of water solvent = Mass of solution - Mass of solute = 1420 g - 894.6 g = 525.4 g = 0.5254 kg.
Molality m = (Moles of solute) / (Mass of solvent in kg) = 14.2 / 0.5254 = 27.03 mol/kg.
Frequently asked questions
What is Volumetric Analysis about?
Comprehensive solutions and study guide for Class 12 Chemistry Chapter 1 Volumetric Analysis covering concentration units, equivalent weight formulas, primary and secondary standards, titration equivalence principles, and indicator selection.
Which topics are covered in Volumetric Analysis?
Class 12 Chemistry “Volumetric Analysis” covers: Concentration Expressions (Molarity, Normality, Molality, ppm); Equivalent Weight of Acids, Bases, Salts, and Redox Reagents; Primary Standards vs Secondary Standards Characteristics; The Law of Equivalence and Titration Equation N1 V1 = N2 V2; pH Curves and Indicator Selection for Neutralization Titrations.
What should I focus on in Volumetric Analysis for the exam?
Solving numericals on standardization of acids/bases, finding percentage purity of chemical samples, and converting between concentration units.
What are the key formulas or definitions in Volumetric Analysis?
Molarity: M = (w * 1000) / (M_w * V_mL); Normality: N = (w * 1000) / (E * V_mL); Equivalent Weight: E = M_w / n-factor; Law of Equivalence: N1 V1 = N2 V2; Relation: N = M * n-factor.
Where can I read the Class 12 Chemistry “Volumetric Analysis” solutions?
Right on this page. They are free and you do not need to sign up. For chapter quizzes and the AI tutor, install the Sikshya Plus app.
Study tips
Do not just read it. Practice it.
You have read the solutions for Volumetric Analysis. Now test yourself, ask the AI tutor and keep your streak going.




- AI quizzes for this chapterTest yourself with instant feedback and explanations after every answer.
- AI tutor, free, 24/7Stuck on a question? Ask in your own words and get a step-by-step explanation.
- 14 AI tools in one appSummarizer, grammar checker, flashcards, essay help, math solver and more.
- Past questions and notesPast papers and your own notes organized chapter by chapter.